DLRRI-026

MoPuW

50 barMax. operating pressure
75 kWHeating power
Cooler update pendingCooling power

About this facility

The mobile pump and heat transfer fluid test stand (MOPUW) enables the demonstration and research of new types of heat transfer fluids for solar thermal power plants and industrial plants on a pilot plant scale.

Sectors and technologies

heat transfer fluid and component testing

Technical specifications

5 parameters
Max. operating pressure50 bar
Heating power75 kW
CHARACTERISTICS Heater3 resistance immersion heaters
Cooling powerCooler update pending
Design flow rate20 m³/h

Available services

  • Testing of components for parabolic troughs solar fields with oil under real operating conditions
  • Characterization of HTF thermal properties
  • Characterization of HTF/HSM chemical stability
  • Qualification HSM/HTF
  • Sensor development and testing
  • Heat Exchangers Characterization
  • Testing TES prototypes using oil as HTF
  • Calibration of synthetic oil mass flow meters
  • Testing of high temperature processes
  • Testing of materials at high temperature
  • Synthesis of materials at high temperature

Contact & links

Dr. rer. nat. Christian Jung - christian.jung@dlr.de