CIEMATRI-001

PTTL Test Loop

Parabolic Trough · 2014

425 °CNominal output temperature [°C]
15 barNominal output pressure [bar abs]

About this facility

The PTTL test facility is a BOP for testing of full parabolic trough loops. It is implemented in a 420 m x 180 m plot of the PSA, and it is composed of two solar fields:

  • The North field is designed to install complete parabolic trough collectors with a maximum unit length of 180 m in E-W orientation. Up to four complete collectors can be installed in parallel.
  • The South field is designed to install complete loops of parabolic trough collectors (PTC), i.e., several collectors connected in series, with a maximum length of 640 m and orientation North—South. Up to four complete loops can be installed in parallel. This outdoor life-size test facility offers the following capacities:
  • Qualification of complete PTC prototypes assessing their optical peak efficiency, incidence angle modifier and thermal losses.
  • Evaluation of durability and reliability of PTC mirrors, receiver tubes, ball-joints, flex hoses, sun tracking systems and all the elements installed in complete rows of collectors.
  • Evaluation of PTC solar field control algorithms.

Sectors and technologies

Power generation, Industrial Process Heat (125-400°C)

Technical specifications

10 parameters
Facility typeParabolic Trough
Year of construction2014
Total number of collectorsThis facility is devoted to test full loops of parabolic trough collectors (PTC)
Collector length/width [m]PTTL North Field allows up to four collectors connected in parallel with maximum length of 180 m. PTTL South Field allows up to four complete loops connected in parallel with maximum length of 640 m.
Collector orientationPTTL North Field: E-W; PTTL South Field: N-S
Working fluidThermal oil Syltherm-800
Nominal output temperature [°C]425 °C
Nominal output pressure [bar abs]15 bar
Power conversion systemAir cooling system that dissipates thermal energy
Technical data of auxiliary equipmentNorth field: oil pump 75 m³/h, air-refrigerated oil cooler 1.5 MWth. South field: oil pump 125 m³/h, air-refrigerated oil cooler 4 MWth. Oil expansion tank: 30 m³; gas-fired oil heater: 250 kW.

Available services

Reflectors and concentrators3 services
  • Geometrical assessment of Solar Concentrators (Single Facets, Point and Line Focus Collectors)
  • Optical and thermal characterization of solar concentrators
  • Parabolic Trough Collector’s Characterization
Absorbers and receivers2 services
  • Outdoor optical and thermal performance of PTC linear receivers
  • Testing of components for parabolic troughs solar fields with oil under real operating conditions
Auxiliary equipment1 service
  • Testing of Rotating Connections for PT receivers (Flexible hoses, ball-joints, etc.)

Contact & links

Diego-César Alarcón-Padilla (diego.alarcon@psa.es)